High Density Polyethylene Duct
In stock

Custom manufacturer 7 yrs CN
About Product
ApplicationHigh Density Polyethylene Duct has been tested and proven under the most severe conditions. From extreme temperatures to abrasive and high tension applications in underground installations, HDPE provides quality service and economy in a wide range of uses. As a smooth and flexible duct for cable, HDPE is unequaled for ease of installation and continuous strength. DescriptionThe duct shall be manufactured from virgin high density polyethylene. The addition of clean rework material is permissible if generated in the manufacturer’s own plant. The ducts are supplied with either smooth, ribbed, or corrugated walls and come in a multitude of colors. The duct shall be capable of being coiled (reeled) in continuous lengths, transported, stored outdoors and subsequently uncoiled for installation – without affecting its properties or performance.Environmental PerformanceThe duct shall perform in underground and above-ground temperature range of minus 300° temperature range of minus 300°F to 1300°F without degradation of material properties. The duct specified for aerial installation shall be ultraviolet light-resistant. It shall be possible to bend the duct to a minimum (supported) radius of 10 diameters. Workmanship The duct shall be free of visible cracks, holes or other physical defects that would degrade its performance. It shall be as uniform as practicable in respect to overall dimensions, color, density, thickness, etc.ColorThe duct for exposed areas (black) shall have a minimum of carbon black. All other colors shall have a UV light stabilizer which will protect the duct for a minimum of 12 months in direct sunlight.MarkingsThe duct shall have a durable identification showing the name or trademark of the manufacturer, duct size (i.e., 2” IPS SCH-80), date and reference code. Duct for electrical cable should have “CAUTION – HIGH-VOLTAGE” printed at regular intervals. Other special markings can be agreed upon between the buyer and seller.CappingThe open ends of each length of reeled duct shall be sealed by plastic caps to prevent the entrance of dirt and/o r moisture.Pull Rope and LubricantThe duct should be equipped with a factory installed rope or tape and pre-lubed to aid in the installation of cable. The rope can be provided with varying strengths as needed for a particular installation. Check with a manufacturer for specifications.CouplingsCouplings should be available to quickly connect the duct and should be air and watertight (i.e., Duct-Lok type couplings in either plastic or aluminum, depending on type of installation). Packaging The duct should be provided on lightweight metal reels in maximum lengths possible with no joints or splices. This will keep coupling requirements to a minimum. Special reel sizes and/ or dimensions should be available for special installations.CorrosionThe duct shall be resistant to most harsh chemicals and/or protected against degradation due to oxidation or general corrosion.InstallationThe duct shall be capable of being direct buried by plowing or trenching with no special consideration to using selective backfill. The duct shall also be capable of being encased in concrete.NOTE: HDPE conduit is manufactured to the dimension and requirements of ASTM F2160. Ovality (out-of-roundness) and curvature are inherent characteristics of coiled, continuous length HDPE conduit. While these conditions are normal and expected and are not a concern in most applications, some installations or applications may require “re-rounding” of the conduit. When this is necessary, ovality should be corrected in the field by processing the conduit through re-rounding and straightening equipment during installation.Tests on Resins and Finished DuctSince specifications vary from customer to customer, we perform in-house lab tests on resins and finished products which include, but are not limited to the following: ASTM D3035: Polyethylene Plastic Pipe Based on Controlled Outside Diameter.ASTM D2447: Polyethylene Plastic Pipe, Schedules 40ASTM D2239: Polyethylene Plastic Pipe Based on Controlled Inside Diameter.ASTM D1248: Polyethylene Plastics Molding and Extrusion Materials. (Type III, Class A, B,or C, Category 5, Grade P34).ASTM D1693: Environmental Stress-Cracking of Ethylene Plastics. (Cond. B, F20/96 HRS.)ASTM D1238: Flow Rates of Thermoplastics by Extrusion Plastometer.ASTM D1505: Density of Plastics by the Density Gradient Technique.ASTM D638: Tensile Properties of Plastics.ASTM D3350: Polyethylene Plastic Pipe and Fittings Materials. (Cell # 335440).NEMA TC 7: Smooth-Wall Coilable Polyethylene Electrical Plastic Duct. Other ASTM tests i.e.: Tensile, Impact etc.ASTM D1505: Density of Plastics by the Density Gradient Technique.ASTM D638: Tensile Properties of Plastics.ASTM D2412: Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading.ASTM D2444: Determination of the Impact resistance of Thermoplastic Pipe and Fittings by Means of a Tup.ASTM D3485: Smooth-Wall Coilable Polyethylene Conduit for Pre-assembled Wire and Cable.ASTM F2160: Standard Specifications for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD).Design ConsiderationsPlease refer to our technical data brochure. This shows different design parameters for polyethylene pipe (i.e., Wall Crushings, Wall Buckling, etc.) as per the various SDR (wall thickness) ratings.Special OptionsStriped Duct – Three longitudinal stripes can be extruded on any standard size of smooth duct of any color. Stripes are approximately 1/8-inch in width (varying slightly according to the duct size). There is no additional charge for Striped Duct.Sequentially-Marked Duct – Duct can be ordered with numbering – every two feet – printed on the duct.Cable in Conduit – Cable can be pre-installed in conduit utilizing the same stringent quality control as pre-roped and pretaped duct. (Request the technical instruction guide for C.I.C. installation.)Fire-Retardant HDPE – AWG offers Fire-Retardant (FR) in any type of duct (orange only). Fire Retardant HDPE has been successfully tested and is offered in the top class, i.e., UL94 V-O only. Because the fire retardant process eliminates UV protection, Fire-Retardant duct must be installed safe from exposure to UV light.All sizes of duct are available with ProPullTM PreLube, ProPullTM Rope or Tape (1130#, 1250#, 1500# or 2500# tensile strength) and spool lengths of your choice up to reel capacity. Selected Sizes available with UL Mark. TYPICAL THERMAL AND ELECTRICAL PROPERTIES OF HDPE DUCTPROPERTYTEST METHODUNITSVALUEVicat Softening Temp.ASTM D 1535°F255°Heat Distortion Temp.ASTM D 648°F172°Thermal ExpansionASTM D 696in/in/°F1 x 10-4Thermal ConductivityASTM C 177BTU in/ft/hrs/°C4.7Volume ResistivityDIN 53482Ω/cm>1016Surface ResistanceDIN 53482Ω>1013Dialectric StrengthDIN 53481KV/cm700-850TYPICAL PHYSICAL PROPERTIES: HIGH MOLECULAR WEIGHT HDPE PRODUCTSPROPERTYASTM (CONDITION)UNITSVALUEDensity (Black)D 1505g/cm30.955Melting PointDSC°F261Melt Index i2.16D 1238 (E)gm/10 min..11Tensile Yield StrengthD 638psi3300Elongation at BreakD 638 (Speciman I)%800Tens. of Modulus of Elast.D 638psi113.000Flexural ModulusD 790psi136.000Vicat Softening Temp.D 1525°F255Brittleness Temp.D 746°F← 103Heat Distortion Temp.D 648°F172Thermal ExpansionD 696in/in/°F1 x 10-4Rockwell Hardness LD 795—49Shore Hardness DD 2240—68The data listed was determined on press molded test specimens, and may therefore deviate from specimens taken from pipes.<span style="font-s
Error: Invalid or empty JSON data
Key attributes
Know your supplier

Website:https://www.buyawg.com/index.html
Company Name:American Wire Group
Location:Miami, FL 33180
Description:Manufacturer and distributor of standard and custom cables, wire, as well as cable accessories. Grounding, static, guy wire, tracer wire, transmission cables, distribution cables, overhead and underground multiplex cables, low voltage cables, medium voltage cables, armored cables, control cables, fiber optic cables, and portable power cables are available. Cable accessories include deadbreak elbows, elbow arrestors, terminations, shearbolt terminals and connectors, cold-applied joints, tubing, and molded parts. Capabilities include cutting, paralleling, and stripping. Markets served include renewable energy, utility, and electric vehicle (EV) infrastructure.
Product Reviews
$0.00
Shipping
Shipping solutions for the selected quantity are currently unavailable
Delivery via maden
Expect your order to be delivered before scheduled dates or receive a 10% delay compensation
Secure payments
Every payment you make on Maden is secured with strict SSL encryption and PCI DSS data protection protocols
Refund policy
Claim a refund if your order doesn't ship, is missing, or arrives with product issues
Frequently bought together
-
-
$0.00
-
Voltage References (Precision)
Sold By: DATEL$0.00
Supplier's popular products
-
Select options This product has multiple variants. The options may be chosen on the product page WishlistPC Power Supplies
Sold By: abdcorp$13.10 – $19.60 -
$0.00
-
$0.00
-
$0.00
-
$0.00























